RF Microwave And Wireless Communication Products
Welcome to our Semi Rigid Cable, semi-rigid and hand formable cable, and RF Microwave cable selection guide if you do not see what you are looking for please send us an email request

 Semi Rigid Cable

1.0 to 18.0 GHz

( Cut in 5 foot lengths Min order 25 feet )

 Cable Selection Guide

Part #

Price per foot

CA50047 

$1.99

Inner Conductor O.D. (in.) .0113 ± .0005
 Inner Conductor Material SCW
Dielectric O.D. (in.) .037 ± .002
Dielectric Material PTFE
Outer Conductor O.D. (in.) .047 ± .002
Outer Conductor Material Copper
Safe Bend Radius
(produced w/ proper tooling) (in.)
1/8
 Weight (lbs./100 ft.) .39
Max. Operating Temp. (°C) 105
Typical Length Made (ft.)  50
Impedance & Tolerance (ohms)  50 ± 2
Dielectric Strength Rating - KVRMS 60 Hz  3.0
Corona Etinction Voltage - KVRMS 60 Hz  1.5
Higher mode cutoff freq. - GHz  110

A (Attenuation, dB/100 ft. at 20°C) and P
(Avg. Power Rating, Watts, unity VSWR, 40°C amb., still air)
Freqency GHz   A          P
1.0 35.3       22
10.0 117        67
18.0 161       4.9

( Cut in 5 foot lengths Min order 25 feet )

 Cable Selection Guide

Part #

Price per foot

AA50085

$2.28

BA50085

$2.99

BA50141

$3.29

Inner Conductor O.D. (in.) .0201 ± .0005 .0201 ± .0005 .0359 ± .0005
 Inner Conductor Material SCW SC SC
Dielectric O.D. (in.) .066 ± .001 .066 ± .001 .1175 ± .001
Dielectric Material PTFE PTFE PTFE
Outer Conductor O.D. (in.) .085 ± .001 .085 ± .001 .141 ± .001
Outer Conductor Material Copper Copper Copper
Safe Bend Radius
(produced w/ proper tooling) (in.)
1/8 1/8 1/4
 Weight (lbs./100 ft.) 1.31 1.31 3.25
Max. Operating Temp. (°C) 125 125 150
Typical Length Made (ft.)  50 50 50
Impedance & Tolerance (ohms)  50 ± 1 50 ± 1 50 ± 1
Dielectric Strength Rating - KVRMS 60 Hz  5.0 5.0 5.0
Corona Etinction Voltage - KVRMS 60 Hz  1.7 1.7 1.9
Higher mode cutoff freq. - GHz  60 60 34
A (Attenuation, dB/100 ft. at 20°C) and P (Avg. Power Rating, Watts, unity VSWR, 40°C amb., still air)
Freqency GHz  A         P  A         P  A         P 
1.0 20.0       99 20.0       99 11.6       365
10.0 71.0       28 71.0       28 44.5       95
18.0 101       20 101       20 62.0       68

( Cut in 5 foot lengths Min order 25 feet )

 Cable Selection Guide

Part #

Price per foot

DA25090

$6.99

Inner Conductor O.D. (in.) .0403 ± .001
 Inner Conductor Material SC
Dielectric O.D. (in.) .073 ± .001
Dielectric Material PTFE
Outer Conductor O.D. (in.) .090 ± .002
Outer Conductor Material Copper
Safe Bend Radius
(produced w/ proper tooling) (in.)
1/4
 Weight (lbs./100 ft.) 1.7
Max. Operating Temp. (°C) 175
Typical Length Made (ft.)  50
Impedance & Tolerance (ohms)  25 ± 2
Dielectric Strength Rating - KVRMS 60 Hz  2.5
Corona Etinction Voltage - KVRMS 60 Hz  1.5
Higher mode cutoff freq. - GHz  46

A (Attenuation, dB/100 ft. at 20°C) and P
(Avg. Power Rating, Watts, unity VSWR, 40°C amb., still air)
Freqency GHz  A         P 
1.0 23.4       160
10.0 82.4       46
18.0 116        33


( Cut in 5 foot lengths Min order 25 feet )

 Cable Selection Guide

Part #

Price per foot

BE50085

$2.99

CE50047

$4.99

Inner Conductor O.D. (in.) .0201±.0005 .0113 ± .0005
 Inner Conductor Material SC SCW
Dielectric O.D. (in.) .066 ± .001 .037 ± .002 
Dielectric Material PTFE PTFE
Outer Conductor O.D. (in.) .085 ± .001 .047 ± .002
Outer Conductor Material Copper,Tin Plated Copper,Tin Plated
Safe Bend Radius
(produced w/ proper tooling) (in.)
1/8 1/8
 Weight (lbs./100 ft.) 1.31 .39
Max. Operating Temp. (°C) 125 105
Typical Length Made (ft.)  50 50
Impedance & Tolerance (ohms)  50 ± 1 50 ± 2
Dielectric Strength Rating - KVRMS 60 Hz  5.0 3.0
Corona Etinction Voltage - KVRMS 60 Hz  1.7 1.5
Higher mode cutoff freq. - GHz  60 110

A (Attenuation, dB/100 ft. at 20°C) and P (Avg. Power Rating, Watts, unity VSWR, 40°C amb., still air)
Freqency GHz  A         P  A        P 
1.0 20.0      99 35.3      22
10.0 71.0       28 117       6.7
18.0 101       20 161       4.9


( Cut in 5 foot lengths Min order 25 feet )

 Cable Selection Guide

Part #

Price per foot

DA50085

$1.49

Inner Conductor O.D. (in.) .0201 ± .0005
 Inner Conductor Material SC
Dielectric O.D. (in.) .066 ± .001
Dielectric Material PTFE
Outer Conductor O.D. (in.) .085 ± .001
Outer Conductor Material Copper
Safe Bend Radius
(produced w/ proper tooling) (in.)
1/8
 Weight (lbs./100 ft.) 1.31
Max. Operating Temp. (°C) 125
Typical Length Made (ft.)  50
Impedance & Tolerance (ohms)  50 ± 1
Dielectric Strength Rating - KVRMS 60 Hz  5.0
Corona Etinction Voltage - KVRMS 60 Hz  1.7
Higher mode cutoff freq. - GHz  60

A (Attenuation, dB/100 ft. at 20°C) and P (Avg. Power Rating, Watts, unity VSWR, 40°C amb., still air)
Freqency GHz  A         P 
1.0 20.0       99
10.0 71.0       28
18.0 101        20


More Cable Products

 



 Request For Quote * Home * Order Entry * Products * Questions Comments


LE FastCounter

You Are Our Most Important Visitor

Copyright (c) 1998 - 2002 HD Communications Corp. 1 Comac Loop,

Ronkonkoma, NY 11779 USA

 Toll Free in USA & Canada (888) 588-3800, Int. Customers Tel. 1 (631) 588-3877

 Worldwide Fax. (631) 588-3879

All rights reserved. Redistribution or republication of these pages in any form requires express written consent.

This website is designed for versions 4.0 or higher of